500mm EU to UK Converter Flue Pipe / Matt Black / With Door

A starter pipe that fits neatly around the flue outlets of contemporary stoves.

The internal drip bead ensures EU type stove outlets conform to UK regulations.


Can be cut to length. Internal diameter 150mm.

 

Email us at info@greymetal.co.uk for lead time.
Only 0 left
£39.00

Secure checkout through Worldpay

Delivery usually within 3-4 days  more about delivery
For more info call 01244 913 320 or email us 

Free  flue design service  -  For a metal chimney quote, fill in one of these forms

 

EU regulations require the pipe fitting around the outside of the flue exit / spigot to allow the smooth flow of the flue gasses. UK regs have it on the inside to let water run into the stove.

This pipe has a flange on the inside of the pipe which acts as a drip bead which causes water to fall inside the stove's flue exit. Each subsequent pipe fits inside the pipe below.

Can be cut and used as an adapter for vitreous enamel pipes*, or as the starter length for further matching black flue pipes.

*pipes must fit inside the internal diameter of 150mm

Details:

European type heavy gauge steel pipe with matt black painted finish.

440 mm Effective length, can be cut to length.

Robust construction of 2mm thick Steel, Type EN 10025

Air tight flush fitting joints (N1 / 40 Pa).

Flush Fitting Joints of European Flue Pipe

For solid fuel appliances,  tested to temperatures up to 500 degrees C.

Used to connect the stove and Flue Liner / Chimney Stack / Twin Wall Flue System.
CANNOT be used to pass through ceilings or walls, or outdoors.

INSTALLATION
Distance to combustible materials: 3 times the diameter of the flue, (wood, plaster board, etc.)

150mm diameter Flue Pipe should be 450mm away from combustible materials.
The smaller spigot end should be pointing downward to allow water to flow within the pipe. (UK building regs)
Joints can be sealed with a fine jointing compound (flueseal, ceramix). Joins between the flue pipe and stove and between the flue pipe and twin wall chimney or flue liner may require a fire proof glass rope also.

MAINTENANCE
Inspect the chimney every 6 months minimum and clean every 12 months, possibly more often when using coal.

Use a pipe with an access door or clean from within the stove.

Specifications
Colour Black
CE Rating EN 1856-2-T400-N1-D-VmL01200-G500
Diameter 150mm
Length 500 mm
Wall Thickness 2 mm
Type (EU / UK) European
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account